The ML-221XX series conventional fire alarm control panels are designed to provide economical solutions for medium and big applications with modern exterior design and Surface mount technology production technology.
◗ Compatible with EN 54-2 and EN 54-4
◗ 2, 4, 8 and 16 zones
◗ 230V AC 50 Hz power supply input
Product codeDescriptionM
The ML-221XX series conventional fire alarm control panels are designed to provide economical solutions for medium and big applications with modern exterior design and Surface mount technology production technology.
◗ Compatible with EN 54-2 and EN 54-4
◗ 2, 4, 8 and 16 zones
◗ 230V AC 50 Hz power supply input
Product codeDescriptionML-22102Conventional fire alarm control panel, 2 zoneML-22104Conventional fire alarm
control panel, 4 zoneML-22108Conventional fire alarm control panel, 8 zoneML-22116Conventional fire alarm control panel,
16 zoneMGRP-64Conventional repeater panelMG-2610MGRP-64 software
Designed to provide economical solutions for small and medium applications with modern exterior design and SMT (Surface Mount Technology) production technology.
◗ Compatible with EN 54-2 and EN 54-4
◗ 2, 4 and 8 zones
Product Code
DescriptionML-2222Conventional fire alarm control panel,
2 zoneML-2224Conventional fire alarm control pa
Designed to provide economical solutions for small and medium applications with modern exterior design and SMT (Surface Mount Technology) production technology.
◗ Compatible with EN 54-2 and EN 54-4
◗ 2, 4 and 8 zones
Product Code
DescriptionML-2222Conventional fire alarm control panel,
2 zoneML-2224Conventional fire alarm control panel,
4 zoneML-2228Conventional fire alarm control panel,
8 zone
Compatible with all Intelligent addressable and conventional panels.
◗ Compatible with EN 54-18 and EN 54-4 standards
◗ 4 supervised sounder output, each are 1A, 24V DC
◗ Sounder outputs are supervised and continuously monitor for open and short circuit.
◗ Direct connection to addressable and conventional systems
◗ Continuous control against
Compatible with all Intelligent addressable and conventional panels.
◗ Compatible with EN 54-18 and EN 54-4 standards
◗ 4 supervised sounder output, each are 1A, 24V DC
◗ Sounder outputs are supervised and continuously monitor for open and short circuit.
◗ Direct connection to addressable and conventional systems
◗ Continuous control against power supply failure
◗ Direct supply from the batteries when the power supply is cut
◗ Battery charge voltage is automatically adjusted according to ambient temperature
Product codeDescriptionML-0314Sounder expansion panel
Ergonomic and user friendly conventional fire alarm detectors are designed for maximum protection with their stability and sensitivity.
◗ Compatible with EN 54-5 and EN 54-7 standards
◗ Twin LED indicators for 360° view
◗ 2 pcs red LEDs (the light flashes continuously in case of fire-situation, the light flashes once per 8 second in case o
Ergonomic and user friendly conventional fire alarm detectors are designed for maximum protection with their stability and sensitivity.
◗ Compatible with EN 54-5 and EN 54-7 standards
◗ Twin LED indicators for 360° view
◗ 2 pcs red LEDs (the light flashes continuously in case of fire-situation, the light flashes once per 8 second in case of normal-status, the light flashes twice per 8 second in case of fault-status)
◗ Microprocessor controlled
◗ Compatible with ML-0140 series mounting base c/w relay
◗ Compatible with ML-0150 series recessed ceiling mounting back box
◗ Compatible with ML-0121 series surface mounting back box
◗ Remote indicator output
◗ Clips switch structure ensures the electrical contact
Product CodeDescriptionML-2110Optical smoke detectorML-2120Fixed heat detectorML-2130Combined heat detectorML-2130BSClass BS heat detector with mounting baseML-2140Multi-Sensor detectorML-0140Detector mounting baseML-0141Mounting base c/w buzzerML-0144Detector mounting base (B class)ML-0150Recessed mounting baseML-0121Surface mounting back box
Photo-electric smoke detector has an infrared photoelectric smoke detection chamber which utilizes the infrared light scatter sensing principle. The detection chamber is protected from dust, insects and other external interferences.
The detector can work either as a fixed heat or rate of rise heat detector. Fire alarm signal is generated in case of 30°C/min or higher heat rise and/or on reaching the threshold of 60°C.
The fire alarm signal generated on reaching the threshold of 60°C.For special orders, fixed heat detectors with different threshold levels can also be manufactured.
The fire alarm signal generated on reaching the threshold of 60°C.For special orders, fixed heat detectors with different threshold levels can also be manufactured.
Multi-sensor has an infrared photoelectric smoke detection chamber utilizing the infrared light scatter sensing principle and a temperature-sensitive thermistor. The detection chamber is protected from dust, insects and other external interferences.
Gas detectors are compatible with conventional fire alarm panels, and provide a sensitive and stable operating performance. User-friendly Mavigard gas detectors provide wide applicability and reliable gas detection.
◗ Compatible with EN 50194-1
◗ System normal operation condition, faults on detector and gas alarm events can be followed via
Gas detectors are compatible with conventional fire alarm panels, and provide a sensitive and stable operating performance. User-friendly Mavigard gas detectors provide wide applicability and reliable gas detection.
◗ Compatible with EN 50194-1
◗ System normal operation condition, faults on detector and gas alarm events can be followed via LEDs
◗ LEDs and buzzer can be tested via test button
◗ Built-in Buzzer
◗ Can be directly connected to loop
◗ 5 years sensor life under normal operating conditions
◗ Max. 127 gas detectors per loop
◗ Relay output models that work with fire and security alarm control panels
◗ Models with two level threshold value
◗ Models with external 24V DC / 230V AC power supply
Product codeDescriptionGDR-1224LLPG (buthane+propane) detector, 12/24V DC with relayGDR-1224MMethane (natural gas) detector, 12/24V DC with relayGDR-220LLPG (buthane+propane) detector, 230V AC with relayGDR-220MMethane (natural gas) detector, 230V AC with relayGD2R-12ECCarbon monoxide gas detector (CO), 12V DC, 2-level alarm output, electrochemicalGD2R-24ECCarbon monoxide gas detector (CO), 24V DC, 2-level alarm output, electrochemicalGD2R-220ECCarbon monoxide gas detector (CO), 230V DC, 2-level alarm output, electrochemicalTGDR-1224MMethane (natural gas) detector, 12/24V DC with relayML-0120Surface mounting back box
LPG (buthane + propane) and natural-gas (methane) are hidrocarbon derivative explosive gases. The detectors respond audible and visually, before the leakage reaches %10 LEL
(lower explosive limit).
Carbon-monoxide is a toxic gas with explosion risk. The detectors respond audible and visual, when the gas concentration reaches to 50 ppm (parts per million).
Ceiling type gas detectors have same size and appearance with smoke detectors. Ceiling type gas detectors require mounting base.
Surface mounting back box is compatible with all Maxlogic and Mavigard single field control modules and gas detectors.
◗ Mathematical modelling technology
◗ Short circuit isolator option
◗ Compatible with EN 54-20 and EN 54-17 standarts
◗ Ability to work Class A, Class B and Class C sensitivity
◗ Wide detection range: 0,005% – 20% (obs/m)
◗ High sensitivity resolution: 0.0001% (obs/m)
◗ Ability to separate dust and smoke
◗ Ability to work Single, U-Type, 2U-Type, H-Type piping system
◗ Ability to give alarm with 4 Alarm levels: Warning, Pre Alarm, Fire 1 and Fire 2
◗ Adjustable fan speeds (1-10 levels)
◗ 4 Alarm output relay (100mA @30V), 2 Fault Output relay (100mA @30V)
◗ Operating status control via LED indicators
◗ Remote control function: Silence, Fault, Reset, Alarm
◗ IP30 protection level
◗ Programming over USB-PC
Single Piping System
– Sampling pipe length: < 150m
– Max hole number: 60
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.
U-Type Piping System
– Sampling Pipe Length: < 250m (every each pipe < 125m)
– Max hole number: Total 60 (every each pipe 30)
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.
H-Type Piping System
– Sampling Pipe Length: < 400m (Every each pipe < 100m)
– Max hole number: Total 60 (Every each pipe 15)
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.
– Sampling Pipe Length: < 400m (Every each pipe < 100m)
– Max hole number: Total 60 (Every each pipe 15)
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.e.
H-Type Piping System
– Sampling Pipe Length: < 400m (Every each pipe < 100m)
– Max hole number: Total 60 (Every each pipe 15)
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.
– Sampling Pipe Length: < 400m (Every each pipe < 100m)
– Max hole number: Total 60 (Every each pipe 15)
– Hole diameter: 2mm
– Ending Cover: Flow can be accelerated with 4-8mm hole.e.
◗ Aircraft hangar
◗ Arsenals
◗ IT centers
◗ Data banks
◗ Valuable document archives
◗ Intensive care rooms
◗ Laboratories
◗ Museum and art galleries
◗ Historical houses and historical artifacts
◗ Scientific research centers
◗ Warehouses
◗ Petrochemical facilities
◗ Transformer buildings
◗ Telecommunication centers and similar structures
Product CodeDescriptionML-2180Maxlogic Conventional Aspirating Smoke
Detector
Maxlogic series conventional sounders provide stable performance in indoor applications and are compatible with all conventional panels.
Maxlogic series conventional sounder beacon generates audible and visual signal, in addition to these features
◗ Compatible with EN 54-3
◗ Surface mount or flush mount
◗ Compatible with all conventional fire alarm panels
Product codeDescriptionML-2410Conventional sounderML-2420Conventional beaconML-2430Conventional sounder & beacon
Maxlogic series conventional sounders are weather-proof audible warning devices and suitable for outdoor use. ◗ Compatible with EN 54-3 and EN 54-23 ◗ Adjustable different 32 voice tone options ◗ Adjustable flash frequency and coverage area ◗ IP33 / IP65 high protection class options ◗ Suitable for outdoor use
◗ White, strong LED flasher
Product Code
DescriptionML-2440Conventional Sounder, Weatherproof (IP33)ML-2450Conventional Beacon, Weatherproof (IP33)ML-2460Conventional Sounder & Beacon, Weatherproof (IP33)ML-2470Conventional Sounder, Weatherproof (IP65)ML-2480Conventional Beacon, Weatherproof (IP65)ML-2490Conventional Sounder & Beacon, Weatherproof (IP65)
Maxlogic conventional system beacon synchronization modules are designed to enable beacons to operate in a synchronized manner regionally.
◗ Compatible with EN 54-18 standards
◗ It is designed to work with Maxlogic & Mavigard Conventional Panel, Addressable panel and Gas Panels
◗ Led’s for Power(Green), Alarm (Red) and Fault(Yellow) conditions.
◗ The ML-2310 model has 1 module activation input and 2 synchronization outputs.
◗ The ML-2311 model has 1 module activation input and 6 synchronization outputs.
Product CodeDescriptionML-2310Maxlogic Conventional System Beacon Synchronization Module, 1 Input/2 OutputML-2311Maxlogic Conventional System Beacon Synchronization Module, 1 Input/6 Output
Designed according to the EN 54-11 standards, with easy to install and easy to use features and useful accessories, the conventional fire alarm manual call points offer superior and stable working performance.
◗ Easy resettable
◗ Compatible with EN 54-11 standards
◗ Surface mount or flush mount
◗ Compatible with all conventional fire alarm panels
◗ Transparent protection cover
Product codeDescriptionML-2710Manual call point, resettableML-0710Transparent protection cover